INTRODUCTION OF THE LABORATORY

radiofrekvencias_vizsgalo_laboratorium_15.jpg

The Radiofrequency Test Laboratory provides an opportunity for electrotechnic-, information-, telecommunication and radio equipment (including standalone and complete systems) EMC directive compliance testing. The RED and EMC directive is to be applied, even if a device that already has a CE marking is integrated inside another product. That is why a product, that is assembled from multiple CE marked units, the whole EMC and RED testing must be carried out for the new product to receive a CE marking. We provide development support- and compliance
testing for CE certification and recertifi according to directives standards, with accredited (MSZ EN ISO/IEC 17025:2018) or not accredited test reports. Furthermore we undertake the complete CE certification process and the complete organization of the directive relevant development support-, verify and compliance tests (RED, EMC, LVD, Safety&Health).

INTRODUCTION OF TESTS

Name of the test The standard on which the test is based  Accredited test Y/N Short description
Testing requirements for household electrical appliances, power tools and similar appliances MSZ EN 55014-1:2017
MSZ EN 55014-2:2015
Y Emission EMC test and immunity EMC test.
Testing of information technology equipment MSZ EN 55024:2017 Y EMC testing of immunity characteristics; determination of limits and measurement methods.
Electromagnetic compatibility testing of multimedia equipment MSZ EN 55032:2015 Y Noise emission EMC test.
EMC test for equipment connected in public low-voltage supply systems, with a rated current not exceeding 16 A per phase and without special conditions MSZ EN IEC 61000-3-2:2019
MSZ EN IEC 61000-3-3:2013
Y EMC testing of harmonic currents; voltage variation, voltage fluctuation and flicker EMC testing.
Testing short-range SRD devices operating between 25-1000MHz MSZ EN 300 220-1:2017
MSZ EN 300 220-2:2018
Y Electromagnetic compatibility and radio spectrum testing.
Testing of data transmission equipment using wideband modulation in the 2.4GHz ISM band MSZ EN 300 328:2017 Y RED investigation of the requirements for data transmission equipment using wideband modulation in the 2.4GHz ISM band.
Electromagnetic compatibility (EMC) testing of radio equipment and services MSZ EN 301 489 family of standards N Investigation of specific conditions for devices operating at frequencies between 9kHz and 246GHz.
Testing of fire detection equipment, components using radio link MSZ EN 54-25:2008 N Performance testing of receivers.
Testing cable networks for television signals, sound signals and interactive services MSZ EN 50083-2:2018 N Electromagnetic compatibility testing.
Testing 9kHz to 25Mhz short range devices (SRD) MSZ EN 300 330:2017 N Testing essential requirements for devices operating at frequencies between 9kHz and 25MHz.
Testing devices from 1GHz to 40GHz MSZ EN 300 440:2010 N Electromagnetic Compatibility and Radio Spectrum Matters (ERM) testing.
Broadband Radio Access Network (BRAN), 5GHz high-speed RLAN testing MSZ EN 301 893:2015 N Examination of specific conditions for broadband devices.
Testing of automatic electrical regulating and control equipment for household and similar use MSZ EN 60730-1:2012 N Testing general requirements.
Environmental resistance tests MSZ EN 60068-2-1:2007 N Cold temperature tests.
Environmental resistance tests MSZ EN 60068-2-2:2008 N Tests at dry warm temperatures.
Electrostatic discharge immunity (EMC) test MSZ EN 61000-4-2:2009 N Definition of ESD test and measurement methods.
Radiated, radio frequency, electromagnetic field immunity test MSZ EN 61000-4-3:2006 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Immunity test against fast electrical transient/burst phenomena MSZ EN 61000-4-4:2011 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Shock wave immunity test MSZ EN 61000-4-5:2014 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Investigation of immunity to conducted disturbances induced by radio frequency fields MSZ EN 61000-4-6:2014 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Investigation of the immunity to mains frequency magnetic field disturbances MSZ EN 61000-4-8:1995 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Investigation of the immunity to voltage sags, short-time voltage drops and voltage variations  MSZ EN 61000-4-11:2005 N Electromagnetic compatibility (EMC) testing, definition of test and measurement methods.
Test on the requirements for general UWB applications MSZ EN 302 065-1:2017 N Examination of individual requirements for UWB applications.
General tests for UWB used by SRD devices ETSI EN 303 883 v1.1.0 N General tests for UWB applications.
Customer technical requirements, parameters, test methods for UWB used by SRD devices according to Directive 2014/53/EU ETSI TS 103 361 v1.1.1 N Tests under Directive 2014/53/EU for UWB applications.
Testing standards for IMT cell networks under Directive 2014/53/EU ETSI EN 301 908-1 v11.1.1 N 2G, 3G, 4G, LTE450 pre-compliance testing.
Directional characteristics study Not relevant N Directional characteristics of antenna parameters from 10 kHz to 40 GHz.
Profit test Not relevant N Antenna parameters gain test from 10 kHz to 40 GHz.
Return Loss Analysis Not relevant N Return Loss analysis of antenna parameters  from 10 kHz to 40 GHz.
VSWR test Not relevant N Test of antenna parameters VSWR from 10 kHz to 40 GHz.
 

If you have not found the right test or you would like to request a customised test, please contact us! 

Drotár István

E-mail: info@rf.sze.hu

Phone:+36-96-613-693

Mobile:+36-30-532-0557

INTRODUCTION OF THE EQUIPMENTS

Name of the equipment Parameters, test range Inquiries/tests
Frankonia anechoic measuring chamber - DC-40GHz Noise emission and immunity EMC test, RED compliance test, antenna parameters test.
MEB GTEM 1250 G-TEM cell - DC-3GHz Radiated radiofrequency immunity test.
EMC measurement room (L3-21/1) - size: 6,2*3,9m Emission EMC test, Immunity EMC test (ESD, EFT, VDIP, Injected current, Harmonics, Flicker).
Agilent E4438C radio frequency signal generator - 250kHz-6GHz Emission EMC test, immunity EMC test, radio equipment parameters test, antenna parameters test.
Rohde & Schwarz BBA100 power amplifier - 9kHz-1GHz Immunity EMC test, radiated radio frequency immunity test.
Amplifier Research 15S1G-3 power amplifier - 1-3GHz Immunity EMC test, radiated radio frequency immunity test.
Amplifier Research FL7006 field strength probe - 100kHz-6GHz
- maximum: 800V/m
Immunity EMC test, radiated radio frequency immunity test.
Rohde & Schwarz CMW 500 Broadband Radio Communication Tester - Multi-RAT signaling
- 70MHz-6GHz
2G, 3G, 4G, LTE450 pre-compliance testing.
Rohde & Schwarz ZVL6 network analyzer - 9kHz-6GHz Return Loss, VSWR test, antenna parameters test.
Agilent E8257D radio frequency signal generator - 250kHz-40GHz Emission EMC test, immunity EMC test, radio equipment parameters test, antenna parameters test.
Rohde&Schwarz ESU-8 transducer - 20Hz-8GHz Emission EMC test, immunity EMC test, radio equipment parameters test, antenna parameters test.
Agilent E4416A power meter - 20Msample/s
- performance measurement: time-gated and free run
- with predefined configurations
Interference emission EMC testing, testing of radio equipment parameters.
Agilent E9327A power measuring head - 50MHz-18GHz Interference emission EMC testing, testing of radio equipment parameters.
Agilent 8487A power measuring head - 50MHz-50GHz Interference emission EMC testing, testing of radio equipment parameters.
Agilent E4446A spectrum analyser - 3Hz-44 GHz Emission EMC test, immunity EMC test, radio equipment parameters test, antenna parameters test.
EMC Partner Transient 3000 EMC test system - IEC 61000-4-2
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- IEC 61000-4-11
- IEC 61000-4-16
- IEC 61000-4-29
- ITU K.20
- ITU K.21
- ITU K.44
- ITU K.45
- ANSI C62.41
EMC immunity test (ESD, EFT, VDIP, Injected current).
EMC Partner Harmonics 1000 EMC tester - 1 phase
- 230V/50Hz
- IEC 61000-3-2 (Harmonics)
- IEC 61000-3-3 (Flicker)
Noise EMC test (Flicker, Harmonics).
EMC Partner PS3 power supply - input: 90-250V, 47-63Hz
- output: 230V/16.7Hz, 230V/50Hz, 115/60Hz, 115/400Hz
- output power: 2000W/2000VA@115V and 3000W/3000VA@230V  
Emission EMC test, Immunity EMC test (ESD, EFT, VDIP, Injected current, Harmonics, Flicker).
Haefely Test AG Onyx 30 ESD pistol - maximum: 30kV ESD testing.
L3Harris Narda-MITEQ AM-1571 low noise preamplifier - 10MHz-1GHz
- Gain: 40dB
Radiated EMC emissions tests.
L3Harris Narda-MITEQ AMF-6F-18004000-37-8P-M low noise preamplifier - 18-40GHz
- Gain: 35dB
Radiated EMC emissions tests.
L3Harris Narda-MITEQ LNA-40-00101800-25-10P low noise preamplifier - 100MHz-18GHz
- Gain: 35dB
Radiated EMC emissions tests.
EMCO 3115 Horn antenna (2pcs) - 1-18GHz Radiated EMC emission tests, immunity EMC tests, radio equipment parameters tests, antenna parameters tests.
EMCO 3116 Horn antenna (2pcs) - 18-40GHz Radiated EMC immunity tests, radiated immunity EMC tests, radio equipment parameters tests, antenna parameters tests.
EMCO 3142C log periodic antenna - 25MHz-1GHz Radiated EMC immunity tests, radiated immunity EMC tests, radio equipment parameters tests, antenna parameters tests.
ARC Seibersdorf PCD3100 Cone dipole antenna - 30MHz-1GHz Radiated EMC immunity tests, radiated immunity EMC tests, radio equipment parameters tests, antenna parameters tests.
Tira TCC 4034 climate chamber - temperature range: (-40°C)-(+140°C) Testing the parameters of radio devices under extreme conditions.

OTHER PROFESSIONAL COMPETENCIES/DEVELOPMENTS

Simulation-based antenna design and antenna fitting, EM field simulation, PCB radiation testing with near field probes, measurement automation, custom EMC/EMI testing, developer consulting, WLAN design, electromagnetic shielding.

 

COLLEAGUES

Name Position Scope of duties, main activities
Drotár István Head of laboratory Management of the labarotory.
Prukner Péter quality management manager Performing quality assurance tasks.
Liszi Máté lab engineer EMC / RED tests.
Lukács Balázs lab engineer EMC / RED tests.
Takács Olivér lab engineer EMC / RED tests.

REFERENCES

  • Carant Antenna Kft.
  • MVM NET Távközlési Szolgáltató Zrt.
  • Oramix Kft.
  • PCB Design Kft.
  • RTS Product Engineering Kft.