The activities of the Building Materials Testing and Building Physics Laboratory cover a wide range, which includes commissioned product testing: the first type testing performed within the framework of the construction product performance constancy testing; expert activities; application testing of construction products; internal and external research and development activities; on-site inspections; building diagnostic tests; qualification tests; and technical development, consulting and other work.

INTRODUCTION OF TESTS

Name of the test The standard on which the test is based  Accredited test Y/N Short description
Hardened concrete tests MSZ EN 12390-3:2009
MSZ EN 12390-7:2009
MSZ EN 12390-8:2009
MSZ 4798:2016
Clause 5.5.5
MSZ CEN/TS 12390-9:2018
MSZ 4798-1:2004
(withdrawn standard)
clause 5.5.6
"MSZ 18290-1:1981
MSZ 4798:2016"
UT 07.03.21 (ÚT 2-3.406)
N - compressive strength, force measurement, length measurement 1,0-85,0 N/mm2
- hardened concrete body density length measurement, mass measurement 150 mm, 700-3500 kg/m3
- watertightness test, penetration depth measurement 1-150 mm
- frost resistance test, mass measurement 0,1-50,0 (m/m%)
- abrasion resistance, length measurement, weight measurement 7,1 cm, 250-1000 g
Fresh concrete tests MSZ EN 12350-2:2009
MSZ EN 12350-4:2009
MSZ EN 12350-5:2009
"MSZ EN 12350-6:2009
MSZ 4798:2016
Clause 5.4.3
MSZ EN 12350-7:2009
Chapter 5"
"MSZ 4714-2:1986
(withdrawn standard)
Chapter 2"
"MSZ EN 12350-1:2009
MSZ EN 12390-2:2009"
N - debris, length measurement 0-300 mm
- compaction factor, mass measurement, volume measurement 0-255 mm
- area, length measurement 100-600 mm
- body density and air voids content, mass measurement, volume measurement 700-3500 kg/m3, 0-20 % air content, pressure measurement 0-20 %
- water content, mass measurement 0,1-15,0 (m/m%)
- sampling of fresh concrete, preparation and handling of specimens for strength testing
Railway cross-sleeper tests  MSZ EN 13230; MÁV internal standards N Static, dynamic and fatigue tests on railway cross beams.
Tests on railway track reinforcements MSZ EN 13481; MÁV internal standards N Static, dynamic and fatigue tests on railway track reinforcements.
Railway track testing MSZ EN 13674; MÁV internal standards N Static, dynamic and fatigue tests on railway tracks.
Tests on thermal insulation materials MSZ EN 12091; MSZ EN 12667 N Thermal testing and measurement of thermal conductivity.
Inspection of road structures [ÚT 2-3.406]; [ÚT 2-2.204]; [ÚT 2-3.408] N On-site strength and mechanical concrete and reinforced concrete testing, on-site steel testing, test loading, deflection measurement, sampling.
Testing of building structures  According to Eurocode N Building diagnostics, various field strength and mechanical tests, sampling.
 

If you have not found the right test or you would like to request a customised test, please contact us! 

Pollák András

E-mail: pollak.andras@ga.sze.hu

Phone: +36-96-503-454

Mobile: +36-30-997-3153

INTRODUCTION OF THE EQUIPMENTS

Name of the equipment Parameters, test range Inquiries/tests
Taurus TCA 300 thermal conductivity meter - Size: minimum 10*10*2cm; maximum 30*30*10cm Thermal testing and measurement of thermal conductivity.
Testo 882 thermal imaging camera - accurate measurement: thermal sensitivity <50mK
- 32° objective
- automatic cold/hot point detection
- built-in digital camera with power LEDs
- real image saved with thermal image
Instrument used in building diagnostics.
Schleibinger freezer-thawing cabinet - programmable
- digital freezer cabinet
- temperature range: (-35°C) - (+40°C)
- internal dimensions: 53*65*155cm
Determination of ice peel.
ELE ADR 2000 concrete breaking machine - Capacity: 2000kN Compressive strength tests.
ZD 40 pushing, pulling, bending machine - German made
- two test rooms
- measuring range: 0-40kN; 0-100kN; 0-200kN; 0-400kN
Bending, tensile and compression testing of various materials.
Matest E161 cement slab bending and crushing machine - measuring range: 0-15kN; 0-250kN
- Distance between pressure plates: 185mm
- Pressure plate diameter: 153mm
- Pressure plate travel length: 45mm
- automatic load speed control
Bending, tensile and compression testing of various materials.
Matest C129 abrasive machine - Boehme scrubbing machine Abrasion of different materials.
Test maturing vat - capacity: 650l Curing of concrete specimens.
Matest A005-4 drying cabinet - capacity: 220l
- Maximum temperature: 200°C
Drying of test materials to constant weight (water content determination and test preparation).
Elcometer MTG6 Ultrasonic Wall Thickness Gauge - measuring range: P-E: 0.63-500mm (0.025-20″), E-E: 2.54-25.40mm (0.100-1.00″)
- accuracy: ±1% or ±0.05mm (0.002″)
Measuring the wall thickness of built-in structures.
Elcometer 510 automatic disconnect device - Measuring range: 2-5Mpa with 20mm diameter bean Adhesion testing of coatings.
Laserliner videoflex G2 mini camera - mini camera with LED lighting
- 7.62cm (3") monitor with 4x digital zoom
- 1.5m long probe
- waterproof Ø9mm camera head
Internal visual inspection of structures.
Testo 206 digital pH meter - measuring range: 0-14pH PH measurement of concrete and various solutions.
Testo 905-T1 insertion probe thermometer - measuring range: (-50°C) - (+350°C) Temperature measurement (environment, fresh concrete...etc.).
BL Compact B2 moisture meter - scan range: 0-199, 9 digits, 0.3-6.0% calculated on dry weight; 0.3-4.0% calculated on CM Measuring the moisture content of building materials.
Elcometer 7410 Concrete Moisture Meter - measuring range: concrete 0-6%, screed 0-10%  Moisture measurement of concretes and screeds.
Matest A059 sitar player - 300mm sitar machine Additive testing.
Flowmeter V-funnel - stainless
- according to EN 12350-9
Consistency testing of self-compacting fresh concrete.
Braking ring area meter (J-ring) - 16 rudas
- According to EN 12350-12
Consistency testing of self-compacting fresh concrete.
L-boxing - stainless
- according to EN 12350-10
Consistency testing of self-compacting fresh concrete.
U-boxing - stainless
- according to EN 11044
Consistency testing of self-compacting fresh concrete.
Test conditions for hardened concrete and precast concrete elements - bending and splitting attachments
- For beams 100*100*400/500 and 150*150*600/750mm
- for 150*300, 160*320mm cylinders
- for 100mm and 150mm cubes
Hardened concrete and reinforced concrete tests.
Hi-Force hydraulic system - maximum load force: 2000kN Testing structures.
HBM Spider 8 measurement system - measuring system up to 16 channels Testing structures.
BISS tiring machine - 0-300kN load at 0-15hz frequency
- 0-15kN under load at 0-30hz frequency
Dynamic fatigue testing of various materials and structures.
Matest C091 automatic bending machine - measuring range: 0-250kN Flexural testing of structures.
HBM displacement transducers - maximum path length: 0-200mm Testing structures.
MOM and Kaliber force gauges - measurement limit: 2000kN Testing structures.

OTHER PROFESSIONAL COMPETENCIES/DEVELOPMENTS

For in-situ tests, it is possible to test larger, complex structures (load, deflection, dynamic tests).

Contributing to grant projects:
- GINOP 2.2.1. project No GINOP-2.2.1-15-2016-00030 - Wood-concrete mule bridges
- GINOP 2.2.1. project GINOP-2.2.1-15-2016-00030 - New generation of mule bridges
- ÚNKP 17-4 - Szabolcs Fischer - Innovative type of crushing analysis of railway crushed stone ballast
- ÚNKP-18-3 - Attila Németh - Laboratory tests of glass fibre reinforced resin bonded-insulated railway rail joints
- ÚNKP-19-3 - Attila Németh - Advanced plastic polymeric straps for railway track joints
- ÚNKP-19-3 - Juhász Erika - Laboratory testing of crushed railway ballast materials with CT 

Completed doctoral researches related to the laboratory from the last 4 years:
- Major Zoltán - Analytical investigation of cast track structures and development of a complex dimensioning method
- Katalin Halvax - Effect of fibre reinforcement on the shear strength of concrete

Assisting in ongoing doctoral research:
- Balázs Eller - Reinforcement of railway substructures with advanced technologies
- Dániel Harrach - Wood-concrete mule bridge structures
- Erika Juhász - Crushing of railway ballast stone materials
- Kitti Károlyfi - New design and evaluation method for exposed concrete surfaces
- Attila Németh - Investigation of the application of polymer-composite belted bonded-insulated rail joints in seamless railway tracks.

 

COLLEAGUES

Name Position Scope of duties, main activities
Pollák András Head of laboratory Managing the laboratory, coordinating, documenting, preparing and performing tests.
Harrach Dániel laboratory assistant Documenting, preparing and carrying out tests.
Németh Attila laboratory assistant Documenting, preparing and carrying out tests.

REFERENCES

- 2015-2017 - MÁV Zrt. - Testing of polymer composite slings in the laboratory and under dynamic loads in track, in bonded insulated joints.
- 2016-2019 - DAV Steel Industry Enterprise Ltd. - Studies related to the development of thin-walled steel disc structure HSV500. 
- 2016-2018 - ConSteel Solutions Ltd. - Experimental investigation and numerical simulation of the behaviour of IQ-FRAME type frame structures. 
- 2016 - Bonar B.V. - Laboratory multi-stage shear loading tests of Georgrid reinforced granular layers. 
- 2016 - Sika Hungária Ltd. - Compliance testing of a concrete chamber brick in steel material channel with cast-in-place rail channel for road railway track system for certification.
- 2016 - Sika Hungária Kft. - Conformity assessment of a type SST18 vb. prefabricated cast-in-place rail track system for certification.
- 2016 - A-Bridge Ltd. - Investigation of the damage to the embankment of Gönyű.
- 2017 - Low & Bonar Hungary Ltd. - Laboratory multi-stage shear loading tests of ENKAGRID "MAX 30 LA" type geogrid reinforced granular layers.
- 2018 - Swietelsky Vasúttechnika Kft. - Investigation of the rail reinforcement of the siding to be installed during the M3 metro line reconstruction using Hilti HRC M22x263 anchor bolts.
- 2018 - Swietelsky Vasúttechnika Ltd. - Investigation of the rail reinforcement of the siding to be installed during the renovation of the M3 metro line using Vossloh M27x290 anchor bolts.
- 2018-2019 - Low & Bonar B.V. - Measurement of capillary discontinuity variation without geomaterial, with several different geomaterials and with one soil material.
- 2019 - Swietelsky Vasúttechnika Ltd. - Laboratory load testing and additional tests of the Vossloh system river track reinforcement of metro line 3 with a larger than planned thickness of the subgrade.
- 2019 - InfraPlan Zrt. - Load capacity testing of fill material in a plain strain model box in the framework of GINOP project.
- 2019 - Swietelsky Vasúttechnika Ltd. - Laboratory tests of LM-S and reference reinforced concrete cross beams removed from the track.